Sure-Seal® IP67 Connector Series

Sure-Seal® connectors offer an unbeatable solution for industrial environments that demand robust, sealed connectivity. These connectors go beyond mere splash-proofing; they’re truly submersible, meeting IP67 and DIN 400 50 standards. Whether it’s marine applications or offshore oil rigs facing corrosive saltwater and extreme weather, Sure-Seal rises to the challenge. It withstands temperatures ranging from -40°F to +221°F, excelling amidst humidity, vibration, and exposure to harsh substances like those found in mining or construction fields.

Maintaining sealing integrity even in the face of brake fluid, gasoline, diesel fuel, antifreeze, ultraviolet, ozone, and steam, Sure-Seal proves its resilience. And with only two parts needed— the connector body and the contacts—installation is straightforward and hassle-free.

These connectors don’t just meet standards; they exceed them. Sure-Seal connectors comply with DOT requirements for shock, vibration, temperature cycling, saltwater spray and immersion, petroleum derivatives, and industrial gas. They also ensure low milli-volt drop and low contact resistance, ensuring reliable performance in any condition.

You can choose from three versions to best suit your needs: Sure-Seal, Mini-Sure-Seal, or Power Sure-Seal. Each variant promises the same level of quality and protection, tailored to fit various applications with precision.

Use filters to narrow down your search…
Full Details Product Image Part Number Series Connector Type Number of Positions Current Rating (Amps per position) wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at contacttype contactsize contactretention mountingtype fasteningtype orientation primarymaterial housingcolor shielding contactshape operatingvoltage dielectricwithstandingvoltage contactresistance insulationresistance operatingtemperature ingressprotection matinglife saltspray heat weatherozoneultraviolet vibration shock agencylisting note warranty
Learn More 120-1832-000 Standard Sure-Seal Plug Housing 1 15 Amps 1 soladminari 28/02/2025 04:30 PM soladminari 20/01/2026 12:45 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1833-000 Standard Sure-Seal Receptacle Housing 1 15 Amps 2 soladminari 28/02/2025 04:30 PM soladminari 20/01/2026 12:46 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1807-000 Standard Sure-Seal Plug Housing 2 15 Amps 37 bevstacy_fi25 26/03/2025 03:01 PM soladminari 20/01/2026 12:47 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-200 Standard Sure-Seal Receptacle Housing 2 15 Amps 38 bevstacy_fi25 26/03/2025 03:08 PM soladminari 20/01/2026 01:16 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) Recuperando datos. Espera unos segundos e intenta cortar o copiar de nuevo. 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1804-000 Standard Sure-Seal Receptacle Housing 2 15 Amps 39 bevstacy_fi25 26/03/2025 03:14 PM soladminari 20/01/2026 01:16 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) Recuperando datos. Espera unos segundos e intenta cortar o copiar de nuevo. .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1808-000 Standard Sure-Seal Plug Housing 3 15 Amps 40 bevstacy_fi25 26/03/2025 03:18 PM soladminari 20/01/2026 01:16 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-201 Standard Sure-Seal Receptacle Housing 3 15 Amps 41 bevstacy_fi25 26/03/2025 03:22 PM soladminari 20/01/2026 01:15 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1805-000 Standard Sure-Seal Receptacle Housing 3 15 Amps 42 bevstacy_fi25 26/03/2025 03:27 PM soladminari 20/01/2026 01:15 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body Recuperando datos. Espera unos segundos e intenta cortar o copiar de nuevo. Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1809-000 Standard Sure-Seal Plug Housing 4 15 Amps 43 bevstacy_fi25 26/03/2025 03:31 PM soladminari 20/01/2026 01:14 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Push-Pull PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-202 Standard Sure-Seal Receptacle Housing 4 15 Amps 44 bevstacy_fi25 26/03/2025 03:35 PM soladminari 20/01/2026 01:14 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1806-000 Standard Sure-Seal Receptacle Housing 4 15 Amps 45 bevstacy_fi25 26/03/2025 03:39 PM soladminari 20/01/2026 01:13 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1841-000 Standard Sure-Seal Plug Housing 5 15 Amps 46 bevstacy_fi25 26/03/2025 03:43 PM soladminari 20/01/2026 01:13 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1839-000 Standard Sure-Seal Receptacle Housing 5 15 Amps 47 bevstacy_fi25 26/03/2025 03:47 PM soladminari 20/01/2026 01:12 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1842-000 Standard Sure-Seal Plug Housing 6 15 Amps 48 bevstacy_fi25 26/03/2025 04:54 PM soladminari 20/01/2026 01:12 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1840-000 Standard Sure-Seal Receptacle Housing 6 15 Amps 49 bevstacy_fi25 26/03/2025 05:07 PM soladminari 20/01/2026 01:11 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1873-000 Standard Sure-Seal Plug Housing 7 15 Amps 50 bevstacy_fi25 26/03/2025 05:12 PM soladminari 20/01/2026 01:11 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1874-000 Standard Sure-Seal Receptacle Housing 7 15 Amps 51 bevstacy_fi25 26/03/2025 05:15 PM soladminari 20/01/2026 01:10 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1865-000 Standard Sure-Seal Plug Housing 8 15 Amps 52 bevstacy_fi25 26/03/2025 05:24 PM soladminari 20/01/2026 01:09 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-305 Standard Sure-Seal Receptacle Housing 8 15 Amps 53 bevstacy_fi25 26/03/2025 05:28 PM soladminari 20/01/2026 01:02 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1866-000 Standard Sure-Seal Receptacle Housing 8 15 Amps 54 bevstacy_fi25 26/03/2025 05:32 PM soladminari 20/01/2026 01:02 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1867-000 Standard Sure-Seal Plug Housing 9 15 Amps 55 bevstacy_fi25 26/03/2025 05:36 PM soladminari 20/01/2026 01:01 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-306 Standard Sure-Seal Receptacle Housing 9 15 Amps 56 bevstacy_fi25 26/03/2025 05:40 PM soladminari 20/01/2026 01:01 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1868-000 Standard Sure-Seal Receptacle Housing 9 15 Amps 57 bevstacy_fi25 26/03/2025 05:43 PM soladminari 20/01/2026 01:01 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1869-000 Standard Sure-Seal Plug Housing 10 15 Amps 58 bevstacy_fi25 26/03/2025 05:49 PM soladminari 20/01/2026 01:00 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-307 Standard Sure-Seal Receptacle Housing 10 15 Amps 59 bevstacy_fi25 26/03/2025 05:53 PM soladminari 20/01/2026 01:00 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1870-000 Standard Sure-Seal Receptacle Housing 10 15 Amps 60 bevstacy_fi25 26/03/2025 05:56 PM soladminari 20/01/2026 01:00 PM Crimp 14-18 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1905-000 Power Sure-Seal Plug Housing 1 85 Amps 61 bevstacy_fi25 26/03/2025 06:06 PM soladminari 20/01/2026 12:59 PM Crimp 4-10 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1903-000 Power Sure-Seal Receptacle Housing 1 85 Amps 62 bevstacy_fi25 26/03/2025 06:12 PM soladminari 20/01/2026 12:59 PM Crimp 4-10 AWG 7.5 lbs (35 N) Minimum Panel Mount Recuperando datos. Espera unos segundos e intenta cortar o copiar de nuevo. Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1906-000 Power Sure-Seal Plug Housing 1 85 Amps 63 bevstacy_fi25 26/03/2025 06:22 PM soladminari 20/01/2026 12:58 PM Crimp 4-10 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-1904-000 Power Sure-Seal Receptacle Housing 1 85 Amps 64 bevstacy_fi25 26/03/2025 06:26 PM soladminari 20/01/2026 12:58 PM Crimp 4-10 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-100 Mini Sure-Seal Plug Housing 2 8 Amps 65 bevstacy_fi25 26/03/2025 06:30 PM soladminari 20/01/2026 12:58 PM Crimp 18-20 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8551-100 Mini Sure-Seal Receptacle Housing 2 8 Amps 66 bevstacy_fi25 26/03/2025 06:34 PM soladminari 20/01/2026 12:57 PM Crimp 18-20 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-101 Mini Sure-Seal Plug Housing 3 8 Amps 67 bevstacy_fi25 26/03/2025 06:38 PM soladminari 20/01/2026 12:57 PM Crimp 18-20 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8551-101 Mini Sure-Seal Receptacle Housing 3 8 Amps 68 bevstacy_fi25 26/03/2025 06:42 PM soladminari 20/01/2026 12:56 PM Crimp 18-20 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8552-102 Mini Sure-Seal Plug Housing 4 8 Amps 69 bevstacy_fi25 26/03/2025 06:46 PM soladminari 20/01/2026 12:48 PM Crimp 18-20 AWG 7.5 lbs (35 N) Minimum Free Hanging (In-Line) Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarzation all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Learn More 120-8551-102 Mini Sure-Seal Receptacle Housing 4 8 Amps 117 soladminari 07/04/2025 04:11 PM soladminari 20/01/2026 12:47 PM Crimp 18-20 AWG 7.5 lbs (35 N) Minimum Panel Mount Push-Pull Stepped plane positive polarization, indexing ribs, and visual polarization all permanently molded into body PVC Nitrile Black Unshielded Circular 400 Vac Maximum 1200 Vac at sea level 10 Milliohms 100 Megohms minimum -40°C ~ 105°C IP67, DIN 400 50, 3 foot depth in 5% salt solution 24 hours minimum, NEMA 6 p 50 cycles minimum (stamped & formed) 100 cycles (machined) to Mil-STD-202D Method 101D .+221F (115 C) for 1000 hours ASTM D-1149 (100pphm) & ASTM D-1171 (outdoor exposure) 5 to 55 Hz .06" DA 1 hour; radial & longitudal axes 50g 11ms, 30 cycles; radial & longitudal axeses UL (E176866) & CSA (LR109871-1) Contacts Not Included 28/02/2026
Series Connector Type Number of Positions Current Rating (Amps per position)
Use filters to narrow down your search…
Full Details Product Image Part Number Series Contact Type Current Rating wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at contacttype contactsize contactretention mountingtype fasteningtype orientation primarymaterial housingcolor shielding contactshape operatingvoltage dielectricwithstandingvoltage contactresistance insulationresistance operatingtemperature ingressprotection matinglife saltspray heat weatherozoneultraviolet vibration shock agencylisting note warranty
Learn More 030-2196-001 Standard Sure-Seal Power, Stamped 15 Amps 71 bevstacy_fi25 28/03/2025 02:42 PM soladminari 20/01/2026 01:24 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 030-2196-006 Standard Sure-Seal Power, Stamped 15 Amps 72 bevstacy_fi25 28/03/2025 04:28 PM soladminari 20/01/2026 01:24 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-1267-001 Standard Sure-Seal Power, Stamped 73 bevstacy_fi25 28/03/2025 05:37 PM soladminari 20/01/2026 01:24 PM Crimp 10 Milliohms 100 Megohms minimum
Learn More 031-1267-005 Standard Sure-Seal Power, Stamped 15 Amps 74 bevstacy_fi25 28/03/2025 05:42 PM soladminari 20/01/2026 01:23 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 030-2196-000 Standard Sure-Seal Power, Stamped 15 Amps 75 bevstacy_fi25 28/03/2025 05:50 PM soladminari 20/01/2026 01:23 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-1267-000 Standard Sure-Seal Power, Stamped 15 Amps 76 bevstacy_fi25 28/03/2025 05:54 PM soladminari 20/01/2026 01:23 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 330-8672-100 Mini Sure-Seal Power, Stamped 8 Amps 77 bevstacy_fi25 28/03/2025 05:58 PM soladminari 20/01/2026 01:23 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-8703-100 Mini Sure-Seal Power, Stamped 8 Amps 78 bevstacy_fi25 28/03/2025 06:02 PM soladminari 20/01/2026 01:22 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 030-2245-002 Power Sure-Seal Machined 85 Amps 79 bevstacy_fi25 28/03/2025 06:19 PM soladminari 20/01/2026 01:22 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 030-2245-001 Power Sure-Seal Machined 85 Amps 80 bevstacy_fi25 28/03/2025 06:22 PM soladminari 20/01/2026 01:22 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-1295-001 Power Sure-Seal Machined 85 Amps 81 bevstacy_fi25 28/03/2025 06:26 PM soladminari 20/01/2026 01:21 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-1294-001 Power Sure-Seal Machined 85 Amps 82 bevstacy_fi25 28/03/2025 06:29 PM soladminari 20/01/2026 01:21 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 030-2244-001 Power Sure-Seal Power, Stamped 85 Amps 83 bevstacy_fi25 28/03/2025 06:32 PM soladminari 20/01/2026 01:21 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 030-2244-002 Power Sure-Seal Power, Stamped 85 Amps 84 bevstacy_fi25 28/03/2025 06:35 PM soladminari 20/01/2026 01:20 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-1299-001 Power Sure-Seal Power, Stamped 85 Amps 85 bevstacy_fi25 28/03/2025 06:38 PM soladminari 20/01/2026 01:20 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Learn More 031-1298-001 Power Sure-Seal Power, Stamped 85 Amps 86 bevstacy_fi25 28/03/2025 06:41 PM soladminari 20/01/2026 01:19 PM Crimp 7.5 lbs (35 N) Minimum 10 Milliohms 100 Megohms minimum
Series Contact Type Current Rating
Use filters to narrow down your search…
Full Details Product Image Part Number Series Tool Type wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at contacttype contactsize contactretention mountingtype fasteningtype orientation primarymaterial housingcolor shielding contactshape operatingvoltage dielectricwithstandingvoltage contactresistance insulationresistance operatingtemperature ingressprotection matinglife saltspray heat weatherozoneultraviolet vibration shock agencylisting note warranty
Learn More SSI-T-TOOL Standard Sure-Seal Insertion Tool 87 bevstacy_fi25 28/03/2025 06:50 PM soladminari 20/01/2026 01:28 PM
Learn More 070306-000 Standard Sure-Seal Insertion Tool 88 bevstacy_fi25 28/03/2025 06:53 PM soladminari 20/01/2026 01:28 PM
Learn More 070235-0001 Standard Sure-Seal Insertion Tool 89 bevstacy_fi25 28/03/2025 07:14 PM soladminari 20/01/2026 01:28 PM
Learn More SS-T-TOOL Standard Sure-Seal Insertion Tool 90 bevstacy_fi25 28/03/2025 07:17 PM soladminari 20/01/2026 01:28 PM
Learn More MSS-T-TOOL Standard Sure-Seal Insertion Tool 91 bevstacy_fi25 28/03/2025 07:22 PM soladminari 20/01/2026 01:27 PM
Learn More MSS-2000 Standard Sure-Seal Insertion Tool 92 bevstacy_fi25 28/03/2025 07:27 PM soladminari 20/01/2026 01:27 PM
Learn More 317-1408-002 Standard Sure-Seal Holding Block 93 bevstacy_fi25 28/03/2025 07:29 PM soladminari 20/01/2026 01:27 PM
Learn More 317-1408-001 Standard Sure-Seal Holding Block 94 bevstacy_fi25 28/03/2025 07:30 PM soladminari 20/01/2026 01:27 PM
Learn More 317-1408-000 Standard Sure-Seal Holding Block 95 bevstacy_fi25 28/03/2025 07:34 PM soladminari 20/01/2026 01:26 PM
Learn More 317-1408-003 Standard Sure-Seal Holding Block 96 bevstacy_fi25 28/03/2025 07:36 PM soladminari 20/01/2026 01:26 PM
Learn More 317-1408-004 Standard Sure-Seal Holding Block 97 bevstacy_fi25 28/03/2025 07:38 PM soladminari 20/01/2026 01:26 PM
Learn More SSI-CS10 Standard Sure-Seal Crimp Tool 98 bevstacy_fi25 31/03/2025 02:31 PM soladminari 20/01/2026 01:25 PM
Learn More SS-CS10 Standard Sure-Seal Crimp Tool 99 bevstacy_fi25 31/03/2025 02:34 PM soladminari 20/01/2026 01:25 PM
Learn More MSS-CS10 Standard Sure-Seal Crimp Tool 100 bevstacy_fi25 31/03/2025 02:37 PM soladminari 20/01/2026 01:25 PM
Series Tool Type
Use filters to narrow down your search…
Full Details Product Image Part Number Series Accessory Type wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at contacttype contactsize contactretention mountingtype fasteningtype orientation primarymaterial housingcolor shielding contactshape operatingvoltage dielectricwithstandingvoltage contactresistance insulationresistance operatingtemperature ingressprotection matinglife saltspray heat weatherozoneultraviolet vibration shock agencylisting note warranty
Learn More 026-0450-000 Standard Sure-Seal Mounting Clip 101 bevstacy_fi25 31/03/2025 03:10 PM soladminari 20/01/2026 02:13 PM
Learn More 317-1398-000 Standard Sure-Seal Boot 102 bevstacy_fi25 31/03/2025 03:14 PM soladminari 20/01/2026 02:13 PM
Learn More 026-0451-000 Standard Sure-Seal Mounting Clip 103 bevstacy_fi25 31/03/2025 03:23 PM soladminari 20/01/2026 02:13 PM
Learn More 317-1397-000 Standard Sure-Seal Boot 104 bevstacy_fi25 31/03/2025 03:26 PM soladminari 20/01/2026 02:12 PM
Learn More 026-0452-000 Standard Sure-Seal Mounting Clip 105 bevstacy_fi25 31/03/2025 03:41 PM soladminari 20/01/2026 02:12 PM
Learn More 029-0263-000 Standard Sure-Seal Mounting Clip 106 bevstacy_fi25 31/03/2025 03:43 PM soladminari 20/01/2026 02:12 PM
Learn More 029-0262-000 Standard Sure-Seal Mounting Clip 107 bevstacy_fi25 31/03/2025 03:45 PM soladminari 20/01/2026 02:12 PM
Learn More 066-8516-000 Standard Sure-Seal Mounting Plate 108 bevstacy_fi25 31/03/2025 03:47 PM soladminari 20/01/2026 02:11 PM
Learn More 317-8657-000 Standard Sure-Seal Boot 109 bevstacy_fi25 31/03/2025 03:49 PM soladminari 20/01/2026 01:32 PM
Learn More 066-8516-002 Standard Sure-Seal Mounting Plate 110 bevstacy_fi25 31/03/2025 03:52 PM soladminari 20/01/2026 01:31 PM
Learn More 225-0093-000 Standard Sure-Seal Wire Filler 111 bevstacy_fi25 31/03/2025 03:54 PM soladminari 20/01/2026 01:31 PM
Learn More 317-8657-002 Standard Sure-Seal Boot 112 bevstacy_fi25 31/03/2025 03:56 PM soladminari 20/01/2026 01:31 PM
Learn More 351-1633-000 Standard Sure-Seal Mounting Ring 113 bevstacy_fi25 31/03/2025 03:59 PM soladminari 20/01/2026 01:30 PM
Learn More 351-1634-000 Standard Sure-Seal Mounting Ring 114 bevstacy_fi25 31/03/2025 04:01 PM soladminari 20/01/2026 01:30 PM
Learn More 351-1640-000 Standard Sure-Seal Mounting Ring 115 bevstacy_fi25 31/03/2025 04:03 PM soladminari 20/01/2026 01:29 PM
Learn More 351-1641-000 Standard Sure-Seal Mounting Ring 116 bevstacy_fi25 31/03/2025 04:05 PM soladminari 20/01/2026 01:29 PM
Series Accessory Type

Features + Benefits

Low installed cost

Resistant to automotive/industrial environments

Wide range of wire gauges and current carrying capability

Water submersible

One-piece connector

Field serviceable

Polarized against mis-mates

Three Sure-Seal versions

Markets Served

Off-Road
Vehicles

Construction
Equipment

Marine
Applications

Agriculture
Equipment

Mining
Equipment

Ground
Transportation